No lights are coming on as if no power. Why would the pump and Polaris stop working at the same time? Thought he motor was defective. Hi Matt, sound like the bearings have gone bad, and now they are so bad that the shaft has locked up or is binding, and that trips the breaker. I have a 2 HP Hayward two speed pump that is on its second season. If the motor shaft and impeller is spinning freely (not clogged or bound-up), then remove the rear cover to the motor. Salt chlorine generators are great products. 3. clogged pump impeller or very dirty filter. Next time it happens, check power on the timeclock, or inspect the motor, looking thru the visual motor check window (again, only on Intermatic clocks), if no power is getting to the clock, replace the breaker, and/or wiring. Automatic reset is immediate once the gas valve relay check results are acceptable. Hi Stephen, could be a loose wire, not just the power wires, but other wires inside the back perhaps, or loose wires on the timeclock or breaker. Hi Tom, there is an o-ring that seals up the tank flange to the valve flange, its usually on the valve, when you remove the valve, might need replacement and/or a good cleaning and lubing. Heater wont ignite when water temp is above 80 degrees. If it is not, re-align your flow switch. The situation is either an air leak in FRONT of the pump, around the pump lid, the pipe coming into the pump, or leaky suction side valves. Holding the shaft stationary (so it wont turn), unthread the impeller, counter clockwise, to remove. Silicone lube can also be used, but dont use petroleum based lubes that can eat the rubber. Grab it and see if it looks/feels loose. Quite a criticism for something costing 33bn-plus. We have a variable speed pump for filter and a single stage pump for cleaner. I used no lube on the gasket. Excessive voltage or amps can cause the problem. Exterior Wall Covering Materials, Sometimes I need to backwash and rinse before the water seems to get going enough to actually circulate, then Im able to switch to filter and it works. This usually means the motor needs to be replaced. Please consider. No moisture. The pool seems to be bonded,I did find that the Aqua Logic Panel is fed from the main electrical panel has no equipment ground, when I established a ground, the motor shortly after burnt up, heard a little crakling and a pop in the motor housing, and little smoke (the breaker did not trip, until the pump smoked out it seemed to be running fine, with a normal amp load. Hi Dave, we are replacing a Hayward superpump 1.5 horsepower with the same pump. Is there a solution for this problem? If the gears are moving, then power should be coming out of the timeclock to the motor. Got another one, it too is doing the same thing. Running very smoothly and pumping very hard. Any idea what could be causing this issue. What would have caused this? The plastic shroud or cover over the impeller? Thank you! Are you using enough DE powder? Override this by moving the Main Switch to Super Chlorinate. Still the same results. Click Here to View Replacement Aquarite Parts 25 This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. If you see any damage, replace your flow switch. Any ideas or what else to check? The second thing that can cause such a problem is if the pump is starved for water, cavitating, because it is too large (hp) for the piping system, or because incoming valves are closed, or pipes are plugged, or clogged. Hmmm, should work? training events, warranty This could drain the pool down to the skimmer, or possibly much lower in some cases, so keep a close eye on any leak and look for signs of worsening. I have digital timer with pump wire going into termials that are screwed down. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. Hose them off well, and then soak them in a DE filter cleaner, in a 5 gallon bucket. Hi Marshall, check that the water level is good, and skimmer weirs are not stuck, blocking water flow into the skimmer, both cases cause the skimmer to suck air, which cause the pump to lose prime. Put it in the line at the pool, and as the pump begins to catch prime, crimp the hose and slowly pull out of the pipe. The Hayward Aqua Plus Automation System should have the capability to accommodate several T-Cell sizes. Thanks. I noticed through the basket lid before pump that there was a stream of water(full stream) but to me it didnt seem like enough water being pulled in. For the priming problem, you may have an air leak on the pump lid or around the pipe coming into the pump. Press and hold the diagnostic button for 3 to 5 seconds. Articles and resources for swimming pool owners and DIYers. Thank you very much in advance. Hi Thomas, the fitting that goes into the pump, was it also replaced? Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools. Does the capacitor look bulged, cracked or leaking? So, grab the opening portion with pliers, while the wrench is holding the shaft still, and turn counter clockwise, it should come off, if it breaks, a new impeller is needed, but thats rare, they usually will budge. Well the electrician said it was a bad motor and to contact hayward to replace. If so pack a bead of Pool Putty around the fitting, or better yet, cut it out and replace it, using lots of Teflon tape or other thread sealant. The HS (High Sense (water temperature) will appear if the water sensor is reading above 105 OR if the sensor detects an increase of more than 6 with-in 60 seconds. Inspect the motor shaft for any obstructions. It only blows air but when I take the lid off water comes out and the basket over flows. You dont need a seal plate kit you can just use the shaft seal SPX1600Z2. My Hayward pump is only about 3 yrs old. We were cleaning our pool filter one day and went to restart the pump and it didnt. Other causes of high pressure could be unrelated to the pump size, such as an obstruction or restriction on the return line, or a partially closed valve, or plugged wall returns, or eyeball fittings in the pool that are too small. You can also contact Hayward Technical Service for help directly at (908) 355-7995. They dont usually begin to flow like a gusher, but a steady trickle. Some inground pools used Flex PVC pipe to connect skimmers, and over 20-30 years, Flex pipe can develop internal nodules like polyps, that restrict flow. Even if it looks good, it could be bad. If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. Step 5: Measure your cells polarity to ensure they meet system parameters. You need to be really sure about the actual salinity reading. Ive waited a few hours and tried again but no luck. If the switch does not close after the blower starts the control will go into lockout with the blower running. Initially, look into the pump/strainer housing. Hayward Super Pump, 1 Hp running on 240V, 3 yrs old If you have an intermatic clock (big yellow dial), there are a series of gears behind the dial, that all need to be engaged. Step 3: Is your cell clean? Hey John When I went out to drain water from the pool it wouldnt turn on. Hi Anmarie, Could be the wrong type of sand, but not likely if the bag said Pool Filter Sand on the label. There is water under the motor not sure from where. "address": "",
Thanks. Reinstalled Same problem recycled power. Second thought is are the pipes plumbed into the valve correct? What would the problem be? 14 x 28 inground, water clear. One of them was arguably the best-constructed route from London [Marylebone] to Manchester. I noticed the pump wasnt running this week and saw the LED display was off and had moisture in it. hayward blue essence troubleshootingautodrive microfiber towels. If it sounds loud and grumbly, that can be a sign of cavitation, being starved for water, from not enough water being supplied (it wants more). Thanks. A pool guy who has since stopped operating put it in. On a Hayward pump with clogged impeller, you can remove the basket, reach through the small hole with your fingers (pump off! To break the rust, you spin the shaft, or impeller. Check all the wire connections inside the motor on the terminal board, the 2 wires and the ground wire. We just verified all our time settings. There should be NO elbow after the flow switch. Third guess is closed or broken valves, clogged filter, clogged impeller, or other obstruction preventing water flow. Thought it was air leak, finally decided to check filters (pressure was 35 lbs after cleaning). just replaced t15 on a rev 1.45 aqua rite and the default salt reading now is 4. This new one when turned on seems to start, and pump, but the breaker shuts off in probably less than a second. Just opening pool. Thanks! We are trying to figure a way to start pumping the water put to clean the pool and get it going but we cant work the pump. You can remove the cartridge, reassemble the filter and run the system, just to verify that the cartridge is the problem. $5.99 $3.99 As low as $1.79 WFO RS-23-SED Sediment Water Prefilter Compatible With Culligan S7011C & 00-4015-38 AquaCleer Good Water Machine $16.99 $9.99 As low as $7.99 However, I havent tried to spin the shaft. A jammed impeller or blown capacitor can lead to a tripped breaker. Hi Ray, the GFI breaker you replaced, is that the pump breaker? I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. Sounds like maybe youve tried it both ways, at water level and below water level? See if your test button has popped out on the outlet, or perhaps you have one on the breaker, a test/reset button. "As for cleaning the pool filters, I do this every couple of days and doesn't help pressure.". Long story short, bought a house that had an above ground pool that would not get the pool clear. Yes, that sounds like a filter problem, clogged up with algae or oily substance. The motor has all of the same specifications of the Hayward motor that is being replaced, what could possibly cause the motor not ot work? Could also be that your vacuum hose has a big split in it if this only happens during vacuuming. In some cases, a small bit of debris (stick or sand) can become lodged between the gasket and the rotor (aka diverter or footpad) and can cause leakage. You will need a new plug and a new outlet and maybe a new pump too (? I was wondering, I have four returns coming into one pipe to the pump basket. Step 2: Verify the accuracy of the salt readings (2700-3400 ppm) with an independent test kit or by taking a water sample to your local pool store for testing. What does F5 mean? Overheating can be a short across the windings, or it can be other major faults within the motor. I replaced my old hayward maxflow pump with the new variable speed sp2670020vsp. If the control exceeds the maximum number of ignition retries or recycles the heater will shut down and go into lockout. I also have voltage (115 volts)on both sides of the fuse holder with no fuse installed. Hi Josh, that sounds like the Display board, a circuit board that controls the display. But most aboveground pool pumps are 115V, and certainly is if it came with the cord. I replaced the impeller ring and noticed it Your salt level is between 2500-2600 parts per million (ppm). check that everything is tight and aligned. Hi Rick, if thats a new thing, there is probably something loose and leaking (air) when the pump shuts off. If the set screws loosen, the impeller can slide forward and contact the pump housing, and grind both the bronze housing and bronze impeller down rapidly. Some pumps are stronger than some hose, so check to see if the hose is not collapsing under the suction, during the issue. 240v Input voltage is present. Also make sure that the impeller wear ring is correctly facing, and that the seal plate and mounting screw are aligned properly, and that the diffuser and diffuser o-ring are seating properly. Ive had the pool for about a month and all has been fine but while I am ordering a new hose is there a replacement hose I can use in the meantime? There could also be a short in the wiring to the pump, or from the breaker to the switch. Hi Stacey, the build-up of pressure usually means that the filter is clogged, as you likely know. "datePublished": "2/24/2015",
Check the wiring in the back of the motor, is the cord firmly attached? Hayward should be able to help, http://www.haywardnet.com see for contact info. "image": {
Craigslist Ny Cars By Dealer Queens,
Laura Cwikowski Bench,
Articles H